Description
Diaper waste incinerator converts waste into ash Combustible gases at 1000°C in primary chamber Secondary Chamber temperature is raised up to 1450°C for at least 2 seconds to incinerate the wastes with a content of more than 1% of halogenated organic substances. The incinerator reduces most combustible solid waste to nearly 1-2 percent by volume and 3 percent by weight.
Operating Principal :
The disposal of waste is based on the principal of incineration of the waste so as to destroy any degradable and infectious material and reduce it volume and mass without producing any type of pollution.
Design:
The design is based on the guidelines set by Central Pollution Control Board (CPCB)-India and normally adopted by military installation all over the country and worldwide. The Efficient power is supplied by electricity as well as oil burners for larger installation.
System Capacity:
The offered system which is operating by automatic gas or Electrical A1 Kanthal/Oil fired burners made with high efficiency Double Chambered Incinerator suitable for disposal of all kind of solid waste. The equipment has got solid state temperature controller with Digital Display, Operating Switches, Indicators and high grade thermal insulation along with control panel with flue discharge system.
Primary Chamber:
– Fully insulated internal refractory lining constructed from high grade refractory brick ensuring a self supporting
– Interlocked arrangement.
– Manually operated access lid.
– Waste ignition burner temperature controlled on-off complete with internal air fans.
– A pre-cast blocks impact zone that protects the refractory lining when loading.
Secondary Chamber:
– Fully insulated internal refractory lining, constructed from high grade low thermal mass insulation.
– Secondary chamber burnout burner temperature controlled on-off complete with internal air fans.
– Integrated combustion burner air fans with automatically controlled distribution to their designated area.
– Temperature sensor mounting point of the chamber ensuring the chamber reaches the necessary temperature.
Fuel Options : Electrical/Diesel LPG
Temperatures
– Main chamber : 850°C – can reach in excess of 1000°C
– Secondary chamber : 1000°C – 1450°C
Burners
– Fully automatic high-efficiency burners with electronic ignition, flame recognition and combustion control devices fitted.
Construction
– Mild Steel welded fabrication consisting of sheet steel and structural section supports.
Ash Removable
Easy and Safe manual ash removal from the primary chamber.
Reviews
There are no reviews yet, would you like to submit yours?